Har du några frågor angående våra produkter? Ring oss på 042-167070
Zoom
M12 male 90° / M8 female 90°
Produkten kan skilja sig från bild

M12 male 90° / M8 female 90°

PUR 3x0.25 bk UL/CSA+drag chain 1,5m
Art.Nr.: 7000-40681-6300150
Alternativ produkt:    7000-40681-0300150
Vikt: 0.054 kg
  I produktion
 Produktjämförelse
Listpris per styck:

Du kanske också gillar

Form
Form 40681
Cables
No./diameter of wires 3× 0.25 mm²
Wire isolation PP (br, bl, bk)
C-track properties 10 Mio.
Material (jacket) PUR (UL/CSA)
Outer Ø 4.1 mm ±5%
Bend radius (moving) 10× outer Ø
Temperature range (fixed) -40...+80 °C
Temperature range (mobile) -25...+80 °C
Cable identification 630
Cable Type 3 (PUR)
Approval (cable) cURus (AWM-Style 20549/10493); CE conform
Cable weight [g/m] 26,40
Material (wire) Cu wire, bare
Resistor (core) max. 79 Ω/km (20 °C)
Single wire Ø (core) 0.1 mm
Construction (core) 32× 0.1 mm (multi-strand wire class 6)
Diameter (core) 3× 0.25 mm²
AWG similar to AWG 24
Material (wire isolation) PP
Material property (wire isolation) CFC-, halogen-, cadmium-, silicone- and lead-free
Shore hardness (wire isolation) 70 ±5 D
Wire-Ø incl. isolation 1.25 mm ±5%
Color/numbering of wires br, bk, bl
Stranding combination 3 wires twisted
Shield no
Material (jacket) PUR
Material property (jacket) CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant
Shore hardness (jacket) 90 ±5 A
Outer-Ø (jacket) 4.1 mm ±5%
Color (jacket) black
chemical resistance good resistance to oil, gasoline and chemicals (EN 60811-404)
thermal resistance flame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2
Nominal voltage 300 V AC
Test voltage 2500 V AC
Current load capacity to DIN VDE 0298-4
Temperature range (fixed) -40...+80 °C, (+90 °C at max. 10 000 operating hours)
Temperature range (mobile) -25...+80 °C, (+90 °C at max. 10 000 operating hours)
Bend radius (fixed) 5× outer Ø
Bend radius (moving) 10× outer Ø
No. of bending cycles (C-track) max. 10 Mio. (25 °C)
Travel speed (C-track) max. 3 m/s
Acceleration (C-track) max. 10 m/s²
Torsion stress ±180°/m
No. of torsion cycles max. 2 Mio. (25 °C)
Torsion speed 35 cycles/min
Jacket Color black
Technical Data
Operating voltage max. 50 V AC/60 V DC
Operating voltage (only UL listed) max. 30 V AC/DC
Operating current per contact max. 4 A
Material group IEC 60664-1, category I
Locking of ports Screw thread (M8/M12×1 mm) recommended torque 0.4/0.6 Nm, self-securing
Compression gland M8 (SW9), M12 (SW13)
Protection IP66K, IP67 inserted and tightened (EN 60529)
Locking material Zinc die casting, nickel-plated
Material PUR
suitable for corrugated tube (internal Ø) M12 (10 mm); M8 (6.5 mm)
Rated surge voltage 1.5 kV
General data
Standards DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8)
Pollution Degree 3
Temperature range -25...+85 °C, depending on cable quality
Kommersiella uppgifter
EAN 4048879801010
eClass 27279218
Förpackningsenhet 1
Kundens tullnummer 85444290
Tillverknings land DE
 
Uppgifter angående artikel:
  • Ladda ner Datablad
  • Ladda ner Approvals and certificates 7000-40681-xxxxxxx_080128-0-000_C6233-01_csau_z_b.pdf
  • Ladda ner Approvals and certificates 7000-40561_18-08.19_ce_z_b.pdf
  • Ladda ner Approvals and certificates 7000-18001_ax_2_i.pdf
  • Ladda ner Approvals and certificates 7000-40681-xxxxxxx_080128-0-000_C6233-01_csa_z_b.pdf
  • Ladda ner China RoHS information EPUP-E_CHR_x_1.pdf
  • Ladda ner Drawing Files 7000-40681_stp_x_a.zip
cULus
* only for products with UL/CSA approved cable
* plus moms, plus frakt