Du kanske också gillar
Internal communication
Current consumption | max. 50 mA |
---|---|
LED display | US: sensor supply and internal supply voltage (green: OK); UA: actuator supply (green: OK) |
Output
Actuator supply UA | 24 V DC (EN 61131-2), max. 4× 2 A |
---|---|
Switching current per output | max. 0.5 A (short-circuit and overload protected) |
Connections
Fieldbus | via internal system connection |
---|---|
Sensor-system/actuator supply | via internal system connection (max. 1× 4 A) / actuators via external cable (max. 4× 2 A) |
I/O ports | FESTO - CPV (SUB-D25) |
General data
Protection | IP67 |
---|---|
Mounting method | 2-hole screw mounting |
Temperature range | 0...+55 °C (storage temperature -20...+70 °C) |
Dimensions H×W×D | 150×30×34.5 mm |
Cables
No./diameter of wires | 4× 4× 0.14 mm² |
---|---|
Material (jacket) | PVC, cross-link safe |
Cable Length | 0.5 m |
Diagnostic
Communication status | via LED |
---|---|
Diagnostic via LED | per module |
Diagnostic via BUS | per module and channel |
Monitoring - under voltage | yes |
Monitoring - no voltage | yes |
Short-circuit and overload | yes |
Actuator warning | per channel via BUS |
Kommersiella uppgifter
EAN | 4048879048415 |
---|---|
eClass | 27371604 |
Förpackningsenhet | 1 |
Kundens tullnummer | 85444290 |
Tillverknings land | DE |